An attached IXPE acoustic pad is a product feature. An IIC or STC value describes the result of a specified acoustic evaluation. Treating those as interchangeable can leave a multifamily flooring submittal incomplete. Before selecting SPC for a Texas apartment project, connect the exact flooring configuration to the report and floor-ceiling construction being evaluated. Impact insulation class, or IIC, concerns impact sound transmission through a floor-ceiling assembly. Laboratory impact testing uses a standardized tapping machine under ASTM E492; the IIC classification is associated with ASTM E989 [2, 3]. Sound transmission class, or STC, concerns airborne sound insulation. ASTM E90 addresses laboratory airborne transmission measurements, with STC classification under ASTM E413 [4, 5]. These ratings address different sound paths. One number cannot stand in for the other. The report needs to identify more than the finished plank. Check the structural floor, slab or deck construction, ceiling condition and any additional layers. A result for one construction does not automatically establish the performance of a different building assembly. ASTM E492 also distinguishes controlled laboratory testing from field conditions, where other sound paths can affect results [2]. Do not present a laboratory value as a guaranteed occupied-building result. Request the laboratory name, report identifier, test date, test method and tested construction. Match the flooring product, overall thickness and pad configuration to the material proposed for purchase. Record whether the report includes a suspended ceiling or other components that the actual project does not have. If a supplier provides only a marketing graphic with a large rating number, request the underlying documentation before using the claim in a submittal. Ask the architect or acoustic consultant to state the applicable project criteria and whether laboratory or field evidence is required. Record the acceptance basis in the submittal. Do not choose a universal IIC or STC target from an online article: the project requirements and applicable rules must be reviewed for that building. An attached pad also does not authorize an additional underlayment. Follow the selected flooring manufacturer’s written installation guidance and obtain clarification for a proposed assembly change. Duratile’s SPC flooring for multifamily projects includes attached IXPE pad configurations. Request the relevant acoustic report for the configuration being considered. Send the proposed color or SKU, project assembly information and acoustic documentation request before finalizing the order. Our Carrollton team can receive the product inquiry and confirm which documents are available for review. Include the square footage, Texas project ZIP code and needed-by date for a separate material and freight quote. Request the product documents before committing to a performance statement. Send your business name, customer type, selected color or SKU, square footage, project ZIP code and needed-by date. (817) 385-0216 · info@duratileus.com 1135 W Trinity Mills Rd, Suite 140, Carrollton, TX 75006Understand what IIC and STC describe
Read the assembly behind the rating
Ask for the complete report
Keep the project requirement in view
Connect documentation to the material order
Technical references
Request trade pricing
Monday–Friday, 8:00 AM–5:00 PM
DURATILE
FLOORING DISTRIBUTORS